Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Cable sheath material: LSZH.
Cable color: Yellow.
Cable length: 5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. No. of poles: 5.
Connection method: Screw-on.
Suitable cable dia: 8 mm (7 to 8) OMRON K2CM-1LS.
Core conductor size: 0.18 to 0.75 mm.
Suitable sheath material: PVC, PE, PUR
K2CM-1LS
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking OMRON K2CM-1LS.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 2.4 m3/min; 60 Hz, 2.7 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa OMRON K2CM-1LS.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 2260 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Detected voltage: AC.
Compact, Economical Plug-in Type Voltage K2CM-1LS.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magneticc relays, as the output relay of the sensor can be driven,
directly with a detection signal K2CM-1LS.
Wide voltage setting range with fine setting capability.