OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K2CM-Q4L datasheet PDF catalog K2CM-Q4L PDF datasheet

OMRON K2CM-Q4L datasheet PDF catalog K2CM-Q4L PDF datasheet

Brand: OMRON
Product model: K2CM-Q4L
Name: Motor Protective Relay
Sort: PDF datasheet
File language: English
File size: 1.35MB
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or PNP input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO);
Data transmission output, RS-485.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse K2CM-Q4L PDF datasheet.
Two display colors (switchable): green/red K2CM-Q4L
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Type of input: AC voltage input.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V K2CM-Q4L PDF datasheet.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K2CM-Q4L PDF datasheet.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeProduct: Straight Bar Nozzle; 500 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K2CM-Q4L datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K2CM-Q4L datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Motor Protective Relay
K2CM-2HAV
OMRON Motor Protective Relay K2CM-2HAV
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-4H
OMRON Motor Protective Relay K2CM-4H
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q1MA
OMRON Motor Protective Relay K2CM-Q1MA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q2LS
OMRON Motor Protective Relay K2CM-Q2LS
Time specification: Instantaneous type. Curre