Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator.
Type: Reverse wiring.
Cable length L: 5.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic OMRON K8AB-TH12S AC100-240.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase)
K8AB-TH12S AC100-240
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON K8AB-TH12S AC100-240.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Power rating: 100 W OMRON K8AB-TH12S AC100-240.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 85 to 132 VAC,
176 to 264 VAC, or 248 to 373 VDC(Select with the switch.).
Output voltage: 36 V VDC.
Output current: 2.8 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warrranty K8AB-TH12S AC100-240.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved foor UL (all models) and CCC (15 to 150-W models) K8AB-TH12S AC100-240.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W.