Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).
Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Cable sheath material: LSZH.
Cable color: Blue.
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for Monitoring 3-phase Power Supplies OMRON S8JX Series.
for Industrial Facilities and Equipment
S8JX Series
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch OMRON S8JX Series. ).
Relay status can be monitored using LED indicator. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) OMRON S8JX Series.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Control supply voltage: 200 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles outt the burned element even if one heater el,
ement among several heater elements has been burned out S8JX Series.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters S8JX Series.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.