Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or PNP input.
Output type: Judgement output, 2 relay contact outputs (SPST-NO);
Data transmission output, RS-485.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse K8DT-AS Series PDF datasheet.
Two display colors (switchable): green/red
K8DT-AS Series
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input K8DT-AS Series PDF datasheet.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points K8DT-AS Series PDF datasheet.
Pulse interval measurement range, maximum measurable from 10msCategory: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputRated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
AC 200, 220, 230, 240, AC 115, 127, 133, 138.
Ideal for 3-phase voltage asymmetry.
monitoring for industrial facilities and equipment.
Monitor volltage asymmetry, phase sequence, and phase loss,
for three-phase 3-wire or 4-wire power supplies with just one Unit K8DT-AS Series datasheet PDF catalog.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 6 AA at 250 VAC (resistive load) K8DT-AS Series datasheet PDF catalog.
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator.