Action mode alarm contact: no lock, a contact.
Category: no auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12).
Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON MYA-NA1.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals
MYA-NA1
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON MYA-NA1.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes OMRON MYA-NA1.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Category: built-in diode (DC).
Contact form: 4DPDT.
Structuure: insert / solder terminal MYA-NA1.
Indicator: with LED indicator light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of thee coil MYA-NA1.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications.