Action mode alarm contact: lock, a contact.
Category: auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12).
Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track OMRON MYA-LA2.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2
MYA-LA2)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles OMRON MYA-LA2.
Contact configuration: Relay, 3PST-NO/SPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment OMRON MYA-LA2.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Soft-start Function Starts Motors Smmoothly,
and Economically MYA-LA2.
The soft-start function allows a smooth startup of motors by,
holding down the starting current, and functions like an inverter.
Comply with UL, CSA, IEC, and JEM requirements.
Mount with screws or to DIN traccks MYA-LA2.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.