OMRON
Home >> Products >> OMRON >> Relay >> General relay >> Special action relay >> MYA-LA12 | OMRON Contact alarm relay circuit unit MYA-LA12

MYA-LA12 | OMRON Contact alarm relay circuit unit MYA-LA12


OMRON MYA-LA12 Product information and technical parameters:
Brand: OMRON
Name: Contact alarm relay circuit unit
Model: MYA-LA12
Action mode alarm contact: lock, a contact.
Category: with fault recovery after the reset confirmation circuit.
Relay number: 3.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12).

Structure: upper end mounting insert / solder terminal.
Contact form: 3PDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V) OMRON MYA-LA12. Isolation: Phototriac coupler.
Zero cross function: Yes MYA-LA12
Indicator: Yes.
Rated output load: 50 A at 200 to 480 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals OMRON MYA-LA12.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps OMRON MYA-LA12.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Type: Standard Models.
Terminals: Plug-in.
Contact form: DPDT.
Internal connections (See note 3.): Non-standard.
With mechanical indicator.
Coil ratings: AC/DC.
New Superr MK Relays MYA-LA12.
Models with Latching Lever Added to the Series.
Same mounting and internal wiring as the previous Super.
MK Relays.
Built-in mechanical indicator enables checking contact operation.
Two modes can be used to check circuits for models with latching lever MYA-LA12.
Nameplate provided on models with latching lever.
All materials are RoHS compliant.
UL and IEC (TÜV) certification.


...More relevant models >>>>
Related download