OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XAA-BCD1 AC100-240 datasheet PDF catalog K3HB-XAA-BCD1 AC100-240 PDF datasheet

OMRON K3HB-XAA-BCD1 AC100-240 datasheet PDF catalog K3HB-XAA-BCD1 AC100-240 PDF datasheet

Brand: OMRON
Product model: K3HB-XAA-BCD1 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Rated primary current: 200 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported K3HB-XAA-BCD1 AC100-240 PDF datasheet. )
Power and current can be measured simultaneously K3HB-XAA-BCD1 AC100-240
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy K3HB-XAA-BCD1 AC100-240 PDF datasheet.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications K3HB-XAA-BCD1 AC100-240 PDF datasheet.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated ffrom the start of operation K3HB-XAA-BCD1 AC100-240 datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-XAA-BCD1 AC100-240 datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products