OMRON K8AB-PM1 Product information and technical parameters:
Brand: OMRON
Name: Three-phase Phase-sequence Phase-loss Relay
Model: K8AB-PM1
Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator.

Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON K8AB-PM1.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that K8AB-PM1
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) OMRON K8AB-PM1.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Power rating: 150 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 15 V VDC.
Output current: 10 A.
Built-in fan: None.
Model with terminal block facing upward OMRON K8AB-PM1.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Collection housing: square type shell embedded ADR shell.
Purpose: high voltage non grounded system; high voltage PC (reactor) grounding system.
Digital ground directional relay K2GS-H type,
Can measure the zero phase current, zero phase voltage of the digital DGR.
And automatic test equipment can be used tto test the relay conveniently K8AB-PM1.
Can be set for the coordination of a small number of hours to adjust the time.
Improve reliability by monitoring function at any time.
LED can be used to confirm the occurrence of anomalies.
The forced actionn of the experimental switch can be easily recognized K8AB-PM1.
Based on the DIN standard size, the depth is only small size 88.5mm. (except for terminal units)