Brand: OMRON
Product model: K8AB-VS2 AC100/115V
Name: Single-phase Voltage Relay
Sort: PDF datasheet
File language: English
File size: 0.83MB
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K8AB-VS2 AC100/115V PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-VS2 AC100/115V
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K8AB-VS2 AC100/115V PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A K8AB-VS2 AC100/115V PDF datasheet.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordiination of digital DCR K8AB-VS2 AC100/115V datasheet PDF catalog.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme K8AB-VS2 AC100/115V datasheet PDF catalog.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.
Related products
OMRON
Single-phase Current Relay
K8AB-AS2 AC100/115V
OMRON Single-phase Current Relay K8AB-AS2 AC100/115V
Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5
OMRON
Single-phase Voltage Relay
K8AB-VW3 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VW3 AC100/115V
Measuring voltage: 20 to 200 V AC/DC, 30 to 3
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS1 AC100/115V
Measuring voltage: 6 to 60 mV AC/DC, 10 to 10
OMRON
Single-phase Voltage Relay
K8AB-VW1 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VW1 AC100/115V
Measuring voltage: 6 to 60 mV AC/DC, 10 to 10