OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5DC-QX2ASM-800 | OMRON Digital Temperature Controller E5DC-QX2ASM-800

E5DC-QX2ASM-800 | OMRON Digital Temperature Controller E5DC-QX2ASM-800

OMRON E5DC-QX2ASM-800 Manual And Instructions
E5DC-QX2ASM-800 datasheetPDF datasheet

OMRON E5DC-QX2ASM-800 Product information and technical parameters:
Brand: OMRON
Name: Digital Temperature Controller
Model: E5DC-QX2ASM-800
Control output: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnot: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.

Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON E5DC-QX2ASM-800.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5DC-QX2ASM-800 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON E5DC-QX2ASM-800.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors OMRON E5DC-QX2ASM-800.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5DC-QX2ASM-800.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5DC-QX2ASM-800.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.


...More relevant models >>>>