Control output: Relay output.
Auxiliary output: --.
Communications: RS-485.
Heater burnot: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC.
for Connections to HMIs and PLCs.
E5@C-800 Series.
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
temperature increases.
Easy connections to a PLC with programless communications.
complete basic functions.
checking alarms, and making settings in a control panel.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo OMRON E5DC-RX0ASM-815.
RoHS compliance for world-wide application
E5DC-RX0ASM-815 Temperature range: 50°C to 150°C.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E5DC-RX0ASM-815. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5DC-RX0ASM-815.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status off the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5DC-RX0ASM-815.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5DC-RX0ASM-815.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.