OMRON
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-MD16TA | OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks DRT2-MD16TA

DRT2-MD16TA | OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks DRT2-MD16TA

OMRON DRT2-MD16TA Manual And Instructions
DRT2-MD16TA datasheetPDF datasheet
DRT2-MD16TA PROGRAMMING MANUAL
DRT2-MD16TA INSTRUCTION Manual

OMRON DRT2-MD16TA Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals with 3-tier Terminal Blocks
Model: DRT2-MD16TA
Specifications: I/O; NPN (input: + common,
output: - common); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.

Power supply voltage: 24 VDC.
Connects to a Total Maximum of Eight,
Digital I/O, Analog I/O, and Relay Output,
Units Compatible with MULTIPLE I/O,
TERMINAL.
Allows flexible combinations of I/O points.
Covering a total cable length of 3 m.
DIN track mounting. Short/disconnection detection: Supported OMRON DRT2-MD16TA.
Specifications: Outputs, PNP (+ common), 16 points.
I/O connections: Clamp terminals DRT2-MD16TA
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance OMRON DRT2-MD16TA.
Single-step wiring by simply inserting pole terminals. Name: Clamp Terminal Blocks.
Specifications: Inputs; 16 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON DRT2-MD16TA.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital I/O.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction. Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiall cost can be reduced DRT2-MD16TA.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee DRT2-MD16TA.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>