Specifications: Inputs; NPN (+ common); 16 inputs.
I/O connections: Sensor connector.
Supplied from the communications connector.
Supplied from the communications connector.
Industry Standards And Can Be Used to Connect.
Special Tools.
functions that provide powerful.
troubleshooting capabilities.
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection.
Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON DRT2-ID16S.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
DRT2-ID16S
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Input capacity: 16 points.
Rated current (ON current):
0 OMRON DRT2-ID16S. 5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply OMRON DRT2-ID16S.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansiion unit per one I/O terminal unit DRT2-ID16S. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software DRT2-ID16S.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.