OMRON DRT2-ID16S-1 Product information and technical parameters:
Brand: OMRON
Name: e-CON Connector Terminals
Model: DRT2-ID16S-1
Specifications: Inputs; PNP (- common); 16 inputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from the communications connector.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensors with Pre-wired Cables without Using,
Special Tools.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection.

Classification: For input.
Internal I/O circuit common: NPN (– common).
I/O points: 8 input points.
Connector Connection Models that.
Allows Easy Connection to Sensors and Output Devices.
Sensors with easy-to-wire connectors are easily,
attached or detached.
Connects to 2-wire sensors.
Remote teaching of the Sensor Terminal is possible OMRON DRT2-ID16S-1.
with the PLC by using output signals of the Sensor Terminal DRT2-ID16S-1
DIN track mounting and screw mounting are available. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON DRT2-ID16S-1.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON DRT2-ID16S-1. Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansionn unit per one I/O terminal unit DRT2-ID16S-1. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software DRT2-ID16S-1.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.


...More relevant models >>>>