Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-SSD-CPAC11 User's Manual.
Digital rotating pulse meter with high speed measurement for 50kHz
K3HB-SSD-CPAC11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the most up toMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC K3HB-SSD-CPAC11 User's Manual.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator K3HB-SSD-CPAC11 User's Manual.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input.
Output type: Judgement output, 3 transistor outputs (NPN open collector);
Data transmission output, None.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Appearance: surface type S5 shell.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,
Caan correspond to the rated value of all generators K3HB-SSD-CPAC11 Manual.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy. Sharing with voltage input, no need to control the power suppply K3HB-SSD-CPAC11 Manual.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED.