OMRON K3HB-SSD-A-DRT1 Manual K3HB-SSD-A-DRT1 Communications Manual

Brand: OMRON
Product model: K3HB-SSD-A-DRT1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.90MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-SSD-A-DRT1 Communications Manual.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-SSD-A-DRT1
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signal, the most up toRated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC.
Ideal for 3-phase Voltage Asymmetry K3HB-SSD-A-DRT1 Communications Manual.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator K3HB-SSD-A-DRT1 Communications Manual. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operationn time,
is indicated from the start of operation K3HB-SSD-A-DRT1 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-SSD-A-DRT1 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,