OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XVD-CPAC11 AC100-240 datasheet PDF catalog K3HB-XVD-CPAC11 AC100-240 PDF datasheet

OMRON K3HB-XVD-CPAC11 AC100-240 datasheet PDF catalog K3HB-XVD-CPAC11 AC100-240 PDF datasheet

Brand: OMRON
Product model: K3HB-XVD-CPAC11 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Rated input voltage: 3-phase 3-wire mode, 200, 220, 230, or 240 VAC.
Ideal for Monitoring 3-phase Power Supplies,
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, phase sequence, and phase loss,
in three-phase three-wire circuits with one unit K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-XVD-CPAC11 AC100-240
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR and MCCB is siimple K3HB-XVD-CPAC11 AC100-240 datasheet PDF catalog.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident K3HB-XVD-CPAC11 AC100-240 datasheet PDF catalog.
Reduce the consumption of VA, reduce the burden of converter.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK3BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-FLK3BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Time interval table
K3HB-PNB-FLK3AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK3AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-L1AT11 AC100-240
OMRON Time interval table K3HB-PPB-L1AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RNB-AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-AT11 AC100-240
Input type: NPN/ voltage pulse input type. E