OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-SSD-CPAC22 Manual K3HB-SSD-CPAC22 User's Manual

OMRON K3HB-SSD-CPAC22 Manual K3HB-SSD-CPAC22 User's Manual

Brand: OMRON
Product model: K3HB-SSD-CPAC22
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.07MB
Function: Phase sequence, phase loss, and temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays K3HB-SSD-CPAC22 User's Manual.
Specially designed for internal motor monitoring; no setting required K3HB-SSD-CPAC22
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Product: Replacement Dischargers (set of 5).
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance K3HB-SSD-CPAC22 User's Manual. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for three-phase,
3-wire or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply K3HB-SSD-CPAC22 User's Manual.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-SSD-CPAC22 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-SSD-CPAC22 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.