Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K3HB-XVA-FLK1AT11 AC100-240 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-XVA-FLK1AT11 AC100-240
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-XVA-FLK1AT11 AC100-240 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-XVA-FLK1AT11 AC100-240 PDF datasheet.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Communication: RS-485; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) deppth K3HB-XVA-FLK1AT11 AC100-240 datasheet PDF catalog.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON//OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the phase difference pulse is increased
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-L1BT11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1BT11 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Time interval table
K3HB-PPB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PPB-FLK1AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RNB-AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-AT11 AC100-240
Input type: NPN/ voltage pulse input type. E