Input type: DC voltage input type.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-XAD-CPAC11 AC100-240 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-XAD-CPAC11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeTime specification: Inverse type K3HB-XAD-CPAC11 AC100-240 PDF datasheet.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XAD-CPAC11 AC100-240 PDF datasheet.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating timme can be set separately K3HB-XAD-CPAC11 AC100-240 datasheet PDF catalog.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K3HB-XAD-CPAC11 AC100-240 datasheet PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.