The temperature, humidity and differential pressure of the cleaning chamber and the simple cleaning room by using PC,
Power consumption and other manufacturing environment.
Implement unified management software.
Centralized management of environmental information in the production site.
Real time analysis of measurement data.
Installation site and measurement conditions can be understood through the map.
Can only be converted to the required data format Excel.
Easy temperature and humidity control with an SD Card. Rated primary current: 200 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power OMRON ZN-SW11-S.
(Classification based on external inputs is also supported
ZN-SW11-S)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power OMRON ZN-SW11-S.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor OMRON ZN-SW11-S.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Category: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: have.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipment, the meeasurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency ZN-SW11-S.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network ZN-SW11-S.
Wide 45mm miniaturization, simple set to the DIN guide.