OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E3X-DA11-S Manual E3X-DA11-S INSTRUCTION sheet

OMRON E3X-DA11-S Manual E3X-DA11-S INSTRUCTION sheet

Brand: OMRON
Product model: E3X-DA11-S
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 13.39MB
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E3X-DA11-S INSTRUCTION sheet.
Event input points: -.
Transfer output: -.
Communication: - E3X-DA11-S
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3X-DA11-S INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 8m E3X-DA11-S INSTRUCTION sheet.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E3X-DA11-S Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products
OMRON
Digital Fiber Amplifier Unit
E3X-DA41AN-S
OMRON Digital Fiber Amplifier Unit E3X-DA41AN-S
Item: Advanced models Analog output models.
OMRON
Dual digital optical fiber sensor
E3X-DA6RM-S
OMRON Dual digital optical fiber sensor E3X-DA6RM-S
E3X-DA6RM-S amplifier unit NPN output
OMRON
Counting sensor
E32-HB04 Series/E3X-DAT_-S Series
OMRON Counting sensor E32-HB04 Series/E3X-DAT_-S Series
Stale detection of chip components in 0402 d
OMRON
Digital Fiber Amplifier Unit
E3X-DAG41-S
OMRON Digital Fiber Amplifier Unit E3X-DAG41-S
Item: Mark-detecting models multiple color l