Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2,700 r/min; 60 Hz, 3,100 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1.5 m3/min.
Maximum static pressure: 50 Hz, 91 Pa; 60 Hz, 85 Pa.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 1,120 g.
Easy One-step Mounting.
simplify installation work.
convenience in confined spaces.
mounting screws).
Optional Replacement Filter and Vent Attachment.
metal blades.
Cable length L: 0.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Shape: tension release (with lock).
Pole number: 14.
Pole pole number: 1.
Minimum packing unit: 200.
Printed board connector core, MIL specification standard OMRON R87B-FA6A15HPFR.
Through the use of new productivity design, high reliability and low price synchronization
R87B-FA6A15HPFR
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved OMRON R87B-FA6A15HPFR.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a .
Cable sheath material: LSZH.
Cable color: Blue OMRON R87B-FA6A15HPFR.
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control R87B-FA6A15HPFR.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads R87B-FA6A15HPFR.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).