OMRON
Home >> Products >> OMRON >> Temperature controller >> Alarm type temperature controller >> K8AK-TH12S 240VAC/DC | OMRON K8AK-TH12S 240VAC/DC

K8AK-TH12S 240VAC/DC | OMRON K8AK-TH12S 240VAC/DC

OMRON K8AK-TH12S 240VAC/DC Manual And Instructions
K8AK-TH12S 240VAC/DC datasheetPDF datasheet

OMRON K8AK-TH12S 240VAC/DC Product information and technical parameters:
Brand: OMRON
Name:
Model: K8AK-TH12S 240VAC/DC
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple.
Setting units (setting range): Setting unit: 10°C/°F*.
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF.

Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID controlTerminal type: Enclosed-terminal Models.
Protective tubing length L: 50cm.
Protective tubing diameter D (mm): 8 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON K8AK-TH12S 240VAC/DC K8AK-TH12S 240VAC/DC
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V) OMRON K8AK-TH12S 240VAC/DC.
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON K8AK-TH12S 240VAC/DC.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
FFurther performance improvement K8AK-TH12S 240VAC/DC.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV K8AK-TH12S 240VAC/DC.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.