Category: ontology; power monitoring.
Application circuit: single phase 2 wire; single phase 3 wire; three-phase 3 wire.
Supply voltage: AC100 ~ 240V (50/60Hz).
Output function: open collector output; cumulative output pulse output; alarm output.
Communication specifications: RS-485.
Memory card function: No K8AK-TH12S 240VAC/DC PDF datasheet.
Simple monitoring of the use of electricity to support energy saving countermeasures
K8AK-TH12S 240VAC/DC
On behalf of the use of the mechanical equipment, the measurement of the initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network K8AK-TH12S 240VAC/DC PDF datasheet.
Wide 45mm miniaturization, simple set to the DIN guide. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485 K8AK-TH12S 240VAC/DC PDF datasheet.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Model: UFR (95L).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 22 relay elements K8AK-TH12S 240VAC/DC datasheet PDF catalog.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K8AK-TH12S 240VAC/DC datasheet PDF catalog.
2 stage cross terminal stand with cover with convenient wiring.