OMRON
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Weighing /mV voltage signal input >> K3HB-VLC-B1 AC100-240 | OMRON Load sensor, mV instrument K3HB-VLC-B1 AC100-240

K3HB-VLC-B1 AC100-240 | OMRON Load sensor, mV instrument K3HB-VLC-B1 AC100-240

OMRON K3HB-VLC-B1 AC100-240 Manual And Instructions
K3HB-VLC-B1 AC100-240 datasheetPDF datasheet

OMRON K3HB-VLC-B1 AC100-240 Product information and technical parameters:
Brand: OMRON
Name: Load sensor, mV instrument
Model: K3HB-VLC-B1 AC100-240
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001m

Unit: CPU Units.
Name: Standard LCD type.
No. of I/O points: 10.
LCD display: Yes.
Power supply voltage: 12 to 24 VDC.
Inputs: 6, 12 to 24 VDC.
Outputs: 4, Transistors.
Buttons, calendar, and clock: Yes.
Analog input: Yes.
Even Broader Applications with Increased.
Functionality and Higher Precision OMRON K3HB-VLC-B1 AC100-240.
Increased functionality in a compact body (70 mm wide × 90 mm high) K3HB-VLC-B1 AC100-240
Easy programming is available using the LCD and operation,
buttons. (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series OMRON K3HB-VLC-B1 AC100-240.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC. Count input: AC/DC multi-voltage input(24 to 240 VAC/VDC).
Max. counting speed: 20 Hz.
Display: 7-segment LCD.
Model: Light-gray body OMRON K3HB-VLC-B1 AC100-240.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models).
Input type: DC voltage input type.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeCategory: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor inpuut, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-B1 AC100-240.
Action determine the color, can switch the green / Red 2 kinds of coolor display K3HB-VLC-B1 AC100-240.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement


...More relevant models >>>>