OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K2CU-F10A-CGS | OMRON Heater Element Burnout Detector K2CU-F10A-CGS

K2CU-F10A-CGS | OMRON Heater Element Burnout Detector K2CU-F10A-CGS

OMRON K2CU-F10A-CGS Manual And Instructions
K2CU-F10A-CGS datasheetPDF datasheet

OMRON K2CU-F10A-CGS Product information and technical parameters:
Brand: OMRON
Name: Heater Element Burnout Detector
Model: K2CU-F10A-CGS
Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.

Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON K2CU-F10A-CGS.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that K2CU-F10A-CGS
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON K2CU-F10A-CGS.
(Not compliant with EC Directives and other safety standards.) Type: Multi-pole, Square Connector.
Terminal Block: Terminal block with M3.5 screws.
Connector: Multi-pole, Square Connector Plugs *2.
No. of poles: 34.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws OMRON K2CU-F10A-CGS.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard.
Terminal blocks available with either M3 or M3.5 screws.
Connecting Cables for Programmable Controllers,
available (sold separately). Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 15 W.
Output voltage: 12 V.
Output current: 1.3 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22 K2CU-F10A-CGS. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply K2CU-F10A-CGS. ).


...More relevant models >>>>