OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON K2CU-F20A-C datasheet PDF catalog K2CU-F20A-C PDF datasheet

OMRON K2CU-F20A-C datasheet PDF catalog K2CU-F20A-C PDF datasheet

Brand: OMRON
Product model: K2CU-F20A-C
Name: Heater Element Burnout Detector
Sort: PDF datasheet
File language: English
File size: 1.26MB
Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 115-120-125-130-135-140-145-150V (8 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1 K2CU-F20A-C PDF datasheet. 4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA K2CU-F20A-C
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-160V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR K2CU-F20A-C PDF datasheet.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except). Measuring current: 0.1 to 1 A AC/DC, 0 K2CU-F20A-C PDF datasheet. 5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 100-115 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manuaal resetting and automatically resetting supported by one Relay K2CU-F20A-C datasheet PDF catalog.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K2CU-F20A-C datasheet PDF catalog.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Heater Element Burnout Detector
K2CU-F20A-FGS
OMRON Heater Element Burnout Detector K2CU-F20A-FGS
Control supply voltage: 220 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-P4A-B
OMRON Heater Element Burnout Detector K2CU-P4A-B
Control supply voltage: 110/220 VAC With vol
OMRON
Heater Element Burnout Detector
K2CU-F10A-DGS
OMRON Heater Element Burnout Detector K2CU-F10A-DGS
Control supply voltage: 110 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-F10A-E
OMRON Heater Element Burnout Detector K2CU-F10A-E
Control supply voltage: 200 VAC With voltage