OMRON G32A-D Series Product information and technical parameters:
Brand: OMRON
Name: Short-circuit Units
Model: G32A-D Series
Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation.

Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 200V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON G32A-D Series.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals G32A-D Series
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON G32A-D Series.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes OMRON G32A-D Series.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified G32A-D Series. Structure: upper end mounting insert / solder terminal.
Contact form: 3PDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil G32A-D Series.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V).


...More relevant models >>>>