OMRON
Home >> Products >> OMRON >> Temperature controller >> Modularization >> E5ZN-2TPH03TC-FLK | OMRON Modular Temperature Controller E5ZN-2TPH03TC-FLK

E5ZN-2TPH03TC-FLK | OMRON Modular Temperature Controller E5ZN-2TPH03TC-FLK

OMRON E5ZN-2TPH03TC-FLK Manual And Instructions
E5ZN-2TPH03TC-FLK datasheetPDF datasheet
E5ZN-2TPH03TC-FLK OPERATION MANUAL
E5ZN-2TPH03TC-FLK INSTRUCTION Manual

OMRON E5ZN-2TPH03TC-FLK Product information and technical parameters:
Brand: OMRON
Name: Modular Temperature Controller
Model: E5ZN-2TPH03TC-FLK
Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.

Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - OMRON E5ZN-2TPH03TC-FLK.
Communication: RS-485.
Event input: 2 points E5ZN-2TPH03TC-FLK
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports OMRON E5ZN-2TPH03TC-FLK.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E5ZN-2TPH03TC-FLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo)) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5ZN-2TPH03TC-FLK.
Through the infrared port can be carried out from the frront of the communication E5ZN-2TPH03TC-FLK.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.


...More relevant models >>>>