OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CN-R2HH03T-W-FLK | OMRON Foundation type temperature controller E5CN-R2HH03T-W-FLK

E5CN-R2HH03T-W-FLK | OMRON Foundation type temperature controller E5CN-R2HH03T-W-FLK

OMRON E5CN-R2HH03T-W-FLK Manual And Instructions
E5CN-R2HH03T-W-FLK datasheetPDF datasheet
E5CN-R2HH03T-W-FLK datasheetPDF datasheet
E5CN-R2HH03T-W-FLK datasheetPDF datasheet
E5CN-R2HH03T-W-FLK Basic TypeUser's Manual
E5CN-R2HH03T-W-FLK User's Manual
E5CN-R2HH03T-W-FLK User's Manual
E5CN-R2HH03T-W-FLK Communications FunctionsUser's Manual
E5CN-R2HH03T-W-FLK USER'S MANUAL
E5CN-R2HH03T-W-FLK Communications FunctionsUser's Manual
E5CN-R2HH03T-W-FLK USER'S MANUAL

OMRON E5CN-R2HH03T-W-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2HH03T-W-FLK
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-R2HH03T-W-FLK.
Ideal for the thermal input devices of Temperature Controllers E5CN-R2HH03T-W-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode OMRON E5CN-R2HH03T-W-FLK.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products OMRON E5CN-R2HH03T-W-FLK.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check tthe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-R2HH03T-W-FLK.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5CN-R2HH03T-W-FLK.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.