Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available.
Compact design (31 × 30 × 30 mm) saves mounting space.
Easy-to-read red LED indicator.
Analog current output models available (E8Y-A@Y).
Pressure port Rc (PT) 1/8 models available (-R) E5EN-Q3H03T-W-FLK-N User's Manual.
EN and UL approved
E5EN-Q3H03T-W-FLK-N Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 27 (39).
Output configuration: PNP.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor E5EN-Q3H03T-W-FLK-N User's Manual.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 4 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP E5EN-Q3H03T-W-FLK-N User's Manual.
Operation mode NC.
A new generation in global applications. Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: NPN output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color.
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
E32-T22R type: standard type; soft (new standard),
Features: with 2 cylinder (small),
Shape / detection distance (mm): 160; 130; 75 (30),
Standard test object
(minimum test object) (mm) 1: 0.5 (0.005),
Fiber element for meeting diversified needsSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RRUN/STOP, alarm), interactive display PV/SV E5EN-Q3H03T-W-FLK-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-Q3H03T-W-FLK-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.