OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CN-R2HH03L-FLK | OMRON Foundation type temperature controller E5CN-R2HH03L-FLK

E5CN-R2HH03L-FLK | OMRON Foundation type temperature controller E5CN-R2HH03L-FLK

OMRON E5CN-R2HH03L-FLK Manual And Instructions
E5CN-R2HH03L-FLK datasheetPDF datasheet
E5CN-R2HH03L-FLK datasheetPDF datasheet
E5CN-R2HH03L-FLK datasheetPDF datasheet
E5CN-R2HH03L-FLK Basic TypeBasic Type
E5CN-R2HH03L-FLK User's Manual
E5CN-R2HH03L-FLK User's Manual
E5CN-R2HH03L-FLK Communications FunctionsUser's Manual
E5CN-R2HH03L-FLK USER'S MANUAL
E5CN-R2HH03L-FLK Communications FunctionsUser's Manual
E5CN-R2HH03L-FLK USER'S MANUAL

OMRON E5CN-R2HH03L-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2HH03L-FLK
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CN-R2HH03L-FLK.
Ideal for the thermal input devices of Temperature Controllers E5CN-R2HH03L-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Protective tubing length: 150mm.
Lead wire length: 4m.
Element type: J (IC).
A Wide Variety of High-precision OMRON E5CN-R2HH03L-FLK.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm OMRON E5CN-R2HH03L-FLK.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermoo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5CN-R2HH03L-FLK.
Through the infrared port can be carried out from the frront of the communication E5CN-R2HH03L-FLK.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.


...More relevant models >>>>