OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CN-R2H03L-FLK | OMRON Foundation type temperature controller E5CN-R2H03L-FLK

E5CN-R2H03L-FLK | OMRON Foundation type temperature controller E5CN-R2H03L-FLK

OMRON E5CN-R2H03L-FLK Manual And Instructions
E5CN-R2H03L-FLK datasheetPDF datasheet
E5CN-R2H03L-FLK datasheetPDF datasheet
E5CN-R2H03L-FLK datasheetPDF datasheet
E5CN-R2H03L-FLK Basic TypeBasic Type
E5CN-R2H03L-FLK User's Manual
E5CN-R2H03L-FLK User's Manual
E5CN-R2H03L-FLK Communications FunctionsUser's Manual
E5CN-R2H03L-FLK USER'S MANUAL
E5CN-R2H03L-FLK Communications FunctionsUser's Manual
E5CN-R2H03L-FLK USER'S MANUAL

OMRON E5CN-R2H03L-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2H03L-FLK
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON E5CN-R2H03L-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5CN-R2H03L-FLK Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON E5CN-R2H03L-FLK.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors OMRON E5CN-R2H03L-FLK.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Current output.
Functions: Heater burnout, No; Mounting option units, No.
Previous model: E5AZ-C3 E5AZ-A3 + E53-AZC.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster samppling at 250 ms E5CN-R2H03L-FLK.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E5CN-R2H03L-FLK.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.