Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Ontology: basic.
Size: 48 x 96mm.
Type: 2 (input).
Control mode: 2 channel standard control /1 channel heating and cooling control /1 channel series control and other functions.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 2 points.
Event entry point: 4.
Serial communication: RS-485 OMRON E5AN-R3HHBT-W-N.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line
E5AN-R3HHBT-W-N
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation OMRON E5AN-R3HHBT-W-N.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: One.
Communications: --.
Heater burnout: -- OMRON E5AN-R3HHBT-W-N.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Size: 96 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: have.
Event input: 4.
Communication: RS-485.
Disconnection detection: 2.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed samplingg to achieve 50ms E5AN-R3HHBT-W-N.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E5AN-R3HHBT-W-N.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.