OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5AN-R3H03T-W-FLK-N | OMRON Foundation type temperature controller E5AN-R3H03T-W-FLK-N

E5AN-R3H03T-W-FLK-N | OMRON Foundation type temperature controller E5AN-R3H03T-W-FLK-N

OMRON E5AN-R3H03T-W-FLK-N Manual And Instructions
E5AN-R3H03T-W-FLK-N datasheetPDF datasheet
E5AN-R3H03T-W-FLK-N Basic TypeBasic Type
E5AN-R3H03T-W-FLK-N User's Manual
E5AN-R3H03T-W-FLK-N User's Manual
E5AN-R3H03T-W-FLK-N Communications FunctionsUser's Manual
E5AN-R3H03T-W-FLK-N INSTRUCTION Manual

OMRON E5AN-R3H03T-W-FLK-N Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5AN-R3H03T-W-FLK-N
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.

Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple.
Setting units (setting range): Setting unit: 10°C/°F*.
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored OMRON E5AN-R3H03T-W-FLK-N.
Temperature monitoring in slim design with a width of just 22 E5AN-R3H03T-W-FLK-N5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output OMRON E5AN-R3H03T-W-FLK-N.
Alarm output status can be retained even if the power,
supply is turned OFF. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater OMRON E5AN-R3H03T-W-FLK-N.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check thhe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5AN-R3H03T-W-FLK-N.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5AN-R3H03T-W-FLK-N.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.


...More relevant models >>>>