OMRON
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-HD16C | OMRON Environment-resistive Terminals with Transistors DRT2-HD16C

DRT2-HD16C | OMRON Environment-resistive Terminals with Transistors DRT2-HD16C

OMRON DRT2-HD16C Manual And Instructions
DRT2-HD16C datasheetPDF datasheet
DRT2-HD16C OPERATION MANUAL
DRT2-HD16C INSTRUCTION Manual

OMRON DRT2-HD16C Product information and technical parameters:
Brand: OMRON
Name: Environment-resistive Terminals with Transistors
Model: DRT2-HD16C
Specifications: Input, NPN (+ common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.

Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON DRT2-HD16C.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site DRT2-HD16C
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sourcing) OMRON DRT2-HD16C.
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNet slave.
Programmable Slaves greatly facilitate device distribution,
and functional organization.
They help standardize programming between units and reduce the amount of,
programming required at the master OMRON DRT2-HD16C.
I/O and operational checks can be performed for each functional unit,
rather than waiting.
for final system assembly, as with conventional distributed I/O systems. Short/disconnection detection: Supported.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materiaal cost can be reduced DRT2-HD16C.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee DRT2-HD16C.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.


...More relevant models >>>>