OMRON
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-AD04H | OMRON Analog I/O Terminals DRT2-AD04H

DRT2-AD04H | OMRON Analog I/O Terminals DRT2-AD04H

OMRON DRT2-AD04H Manual And Instructions
DRT2-AD04H datasheetPDF datasheet
DRT2-AD04H PROGRAMMING MANUAL
DRT2-AD04H INSTRUCTION Manual
DRT2-AD04H INSTRUCTION Manual

OMRON DRT2-AD04H Product information and technical parameters:
Brand: OMRON
Name: Analog I/O Terminals
Model: DRT2-AD04H
Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications.

Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common OMRON DRT2-AD04H.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation DRT2-AD04H
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled OMRON DRT2-AD04H.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system OMRON DRT2-AD04H.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connections: Fujitsu connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. classificationn: Relay output DRT2-AD04H.
I/O points: 16 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W xx H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models DRT2-AD04H.
DIN track mounting and screw mounting are available.


...More relevant models >>>>