Model : CVM1D-CPU21.
For duplex system requires two.Available on either 3.5” or 5.25” floppy disks.C500-AS Special I/O Unit ASCII Unit C500-ASC04.Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 150 VA max OMRON CV1000-DM151.
Output capacity: 8 A, 5 VDCModel : CV1000-CPU01-V1.
SFC / Ladder 1, 024 points (with RAM62K words, the top internal link)
CV1000-DM151I/O Cable (for I/O to Interface Racks) 10 m (L) CV500-CN132CV500-BS CPU Bus Unit BASIC Unit CV500-BSC11.
RS-232C: 2 ports, RS-422: 1 port.Model: C500-CPU11-V1.
C500-CP CPU CPU MODULE JAPANESE C500-CPU11-V1Model : CV500-CN432.
Cable I / O connection.
40M cable length OMRON CV1000-DM151. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223-E.
4-MB memory; w/floating-point processor.Model : C500-PS223.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.C500-ID I/O Unit DC Input 64 pts C500-ID219(3G2A5-ID219).
DC24V 7mA.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223.
4-MB memory; w/floating-point processor.The unit comes with coaxial type OMRON CV1000-DM151. CV500-RM SYSMAC BUS Remote I/O Master Unit (optical) CV500-RM211.
Light type.C500-ID I/O Unit DC Input 16 pts 8 pts/common C500-ID112.
DC5-12V 6mA.C500-OC I/O Unit Transistor Output 16 pts C500-OC223-E(3G2A5-OC223-E).
AC250/DC24V 2A.C500-OD I/O Unit Transistor Output 16 pts C500-OD217(3G2A5-OD217).
DC12-24V 1A.Model: C500-ETL01.
C500-ET Special I/O Unit Educational Tool I/O Unit C500-ETL01.The initial configuration of the G language unit in the industry due to the use of G language,
Complex processing procedures do not need to be able to make the ladder diagram.
The realization of the first 1 axis simultaneous control of 4 axis simultaneous control in the industry is due to the multi task function,
Can be executed at the same time or the 2 axis simultaneous control of 4 axes, and then can achieve the 4 axis independent control, etc.
Up to 8 units can be installed CVM1 8 units can be installed 1 units, can control up to 32 axes.
Applicable to ABS encoder by standard,
Applicable to the ABS tyype (absolute output) encoder, so after the emergency stop, no need to search for the origin, etc CV1000-DM151. .
S curve also according to the standard configuration plus deceleration curve, in addition to the trapezoidal outside,
Also configured too suppress the mechanical vibration of the S shape curve CV1000-DM151.
Program login maximum of up to 100
G language can be programmed with the MC support software G