File size: 3.41MB
Name: SYSMAC LINK Co-axial Power Supply.
Model: C200HS-SLK22.
Model: C200H-OD219.
No. of points: 64 pts.
Specifications: 4.5 VDC, 16 mA to 26.4 VDC, 100 mA..
Weight: 250g max.I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP223 CV1000-CPU01 Replacement Guide.
4-MB memory; w/floating-point processor CV1000-CPU014 platinum resistance thermometer inputs Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 24 points.
Outputs points: 16 points.Unit type: CJ1 Basic I/O Units.
Product name: Triac Output Unit.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC, 0 CV1000-CPU01 Replacement Guide. 6A;
Commons, 8 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.22A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CV1000-CPU01 Replacement Guide.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 24VDC, 7mA,
12 to 24 VDC, 0.5 A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, NN, CE CV1000-CPU01 Manual.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Moddel: C200H-TS001 CV1000-CPU01 Manual.
Temperature sensor: Thermocou-ples: K(CA), J(IC)(selectable).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).
Related products
OMRON
Data memory expansion unit
CV1000-DM251
OMRON Data memory expansion unit CV1000-DM251
Model : CV1000-DM251. Availale CV1000/2000/
OMRON
CPU
C200H-CPU01-E
OMRON CPU C200H-CPU01-E
C200H-CPU01-E/C200H-CPU03-E CPUs High Spec,
OMRON
CPU
CV1000-CPU01-EV1
OMRON CPU CV1000-CPU01-EV1
Model : CV1000-CPU01-EV1. SFC / Ladder 1, 02
OMRON
CPU
CV2000-CPU01-V1
OMRON CPU CV2000-CPU01-V1
Model : CV2000-CPU01-V1. SFC / Ladder 2, 048