Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
1/4,000(Settable to 1/8,000)*2 .
(250 μs/point can also be set.)*2.
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Models with Direct Conversion Join the Lineup.
signals into binary data.
data into analog output signals.
Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 24VDC, 7mA,
12 to 24 VDC, 0.5 A;
Commons, 16 points, 1 common;
External connection, MIL connector OMRON CJ1W-AD041-V1.
No. of words allocated: 2 words.
Current consumption: 5V, 0
CJ1W-AD041-V113A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. Name: Loop-control CPU Unit.
I/O bits: 960 bits.
Program capacity: 20K steps OMRON CJ1W-AD041-V1.
DM words: 32K words.
EM words: 32K words × 1 bank E0_00000 to E0_32767.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Product name: CJ2M (Built-inEtherNet/IP) CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
10K steps;Data memorycapacity, 64K words,
(DM: 32K words, EM: 32K words ×1 bank);
LD nstruction execution time, 0 OMRON CJ1W-AD041-V1. 04 μs;
EtherNet/IP function: YES;
Option board slot: YES.
Current consumption (A): 5V, 0. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000).
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
Externall connection: Removable terminal block CJ1W-AD041-V1.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analoog Input Units for converting analog input,
signals into binary data CJ1W-AD041-V1.
Analog Output Units for converting binary ,
data into analog output signals.