Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits:
100 to 120/200 to 240 VAC (switchable), APF/PCF.100 to 120/200 to 240 VAC (Supports SYSMAC LINK and SYSMAC NET Link Systems.)Model: C200H-PS211.
Supply voltage: 24VDC.For 8-slot Backplane.Connects Power Supply Adapter and SYSMAC NET Link Unit.
For 1 Unit.For 10-slot Backplane.Name: Heat/Cool Temperature Control Module OMRON C200HS-INT01.
Model: C200H-TV002.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U
C200HS-INT01
Control output: Voltage output(transistor output used for cooling outputs).Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Model: C200H-MR832.
Description: RAM, 8K words, capacitor back-up OMRON C200HS-INT01. no clock.Name: Cam Positioner Module.
Model: C200H-CP114.
Output points: 48 points (16 external output points, 32 internal output points).
External outputs: NPN transistor open collector (withphoto-coupler insulation)
Switching capacity: 100 mA at 24 VDC Simultaneous OUM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0 OMRON C200HS-INT01. 1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV003.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Current output(transistor output used for cooling outputs).Model: C200HW-COM05-V1.
Specifications: Two RS-232C ports and a protocol macro function.For 3-slot Backplane.C200H Accessory Programming Console Adapter C200H-BP001.Name: Temperature Sensor Module.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).C200HW Communications Interface MModule C200HW-PRM21C200HS-CPU33-E CPU
High-Performance CIM Version, Built-in RS-232C Port
The C200HS-CPU31-E and C200HS-CPU33-E controller offers the same basic functionality as the C200HS-CPU01-E/CPU03 controllers C200HS-INT01.
This CPU may be ussed ineither SYSMAC NET and/or SYSMAC LINK communication systems C200HS-INT01.