3G3AX-RBU41 | OMRON Regenerative braking unit 3G3AX-RBU41


OMRON 3G3AX-RBU41 Product information and technical parameters:
Brand: OMRON
Name: Regenerative braking unit
Model: 3G3AX-RBU41
Level: 3 phase 400V level.
Connecting resistance: 34 or more.
Internal resistance value: 120W, 180W * 2 (series).
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter.

Function name: 3 phase 200V.
Power: 3.7KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.0KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170.5mm.
Mechanical automation concept OMRON 3G3AX-RBU41.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-RBU41
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Frequency converter input power: 3 phase AC400V OMRON 3G3AX-RBU41.
Weight: 9.0KG.
Standard applicable line diameter: 60 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Frequency converter input power: 3 phase AC400V.
Weight: 3.9KG.
Standard applicable line diameter: 14 square mm or more.
Used to suppress harmonic currents generated by a transducer OMRON 3G3AX-RBU41.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 1.25 square mm, 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Specification: three phase 400V.
Power: 132KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 120kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The hhigh functional specifications are concentrated in the compact 3G3AX-RBU41.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software. 3G3AX-RBU41.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.