OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON 3G3AX-MX2-ECT Manual 3G3AX-MX2-ECT Communications Manual

OMRON 3G3AX-MX2-ECT Manual 3G3AX-MX2-ECT Communications Manual

Brand: OMRON
Product model: 3G3AX-MX2-ECT
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 13.64MB
When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Box protection class: plastic, IP00 3G3AX-MX2-ECT Communications Manual.
Terminal size: M4.
Line diameter: 2 square mm 3G3AX-MX2-ECT
Weight: 0.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Level: 3 phase 400V level.
Connecting resistance: 34 or more.
Internal resistance value: 120W, 180W * 2 (series).
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time 3G3AX-MX2-ECT Communications Manual.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter. Inverter input power: 3 phase / single phase AC200V.
Weight: 1.6KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer 3G3AX-MX2-ECT Communications Manual.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Inverter input power: 3 phase / single phase AC200V.
Weight: 3.6KG.
Standard applicable line diameter: 8 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 100A.
Weight: 8.4KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Function name: 3 phase 200V.
Power: 15KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 7.4KG.
Dimension (w * h) 350mm *:220.
Outline dimension (deep):175mmm 3G3AX-MX2-ECT Manual.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G3AX-MX2-ECT Manual. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.
Related products
OMRON
DC reactor
3G3AX-DL2110
OMRON DC reactor 3G3AX-DL2110
Inverter input power: 3 phase / single phase
OMRON
Input noise filter
3G3AX-NFI46
OMRON Input noise filter 3G3AX-NFI46
Box protection class: plastic, IP00. Terminal
OMRON
DC reactor
3G3AX-DL4110
OMRON DC reactor 3G3AX-DL4110
Frequency converter input power: 3 phase AC40
OMRON
DC reactor
3G3AX-DL2022
OMRON DC reactor 3G3AX-DL2022
Inverter input power: 3 phase / single phase