OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-XVD-A-DRT1 Manual K3HB-XVD-A-DRT1 Communications Manual

OMRON K3HB-XVD-A-DRT1 Manual K3HB-XVD-A-DRT1 Communications Manual

Brand: OMRON
Product model: K3HB-XVD-A-DRT1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.83MB
Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 1 to 2 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-XVD-A-DRT1 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-XVD-A-DRT1
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-XVD-A-DRT1 Communications Manual. Detect abnormal voltages applies to equipment to,
protect against equipment failure.
Monitor for overvoltages and undervoltages,
simultaneously with one Relay.
Monitor AC or DC voltages with one Relay.
Settings for the operating value, hysteresis, and operating time.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work K3HB-XVD-A-DRT1 Communications Manual.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination beetween OCR and MCCB is simple K3HB-XVD-A-DRT1 Manual.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident K3HB-XVD-A-DRT1 Manual.
Reduce the consumption of VA, reduce the burden of converter.
Related products
OMRON
Voltage and current panel meter
K3HB-XVA-BCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-BCD1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-CPAC11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-CPAC11 AC/DC24
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XVA-T11 AC/DC24
OMRON Voltage and current panel meter K3HB-XVA-T11 AC/DC24
Type of input: AC voltage input. Output type