OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-HTA-BCD1 Manual K3HB-HTA-BCD1 Communications Manual

OMRON K3HB-HTA-BCD1 Manual K3HB-HTA-BCD1 Communications Manual

Brand: OMRON
Product model: K3HB-HTA-BCD1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-HTA-BCD1 Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-HTA-BCD1
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-HTA-BCD1 Communications Manual. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-HTA-BCD1 Communications Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically reesetting supported by one Relay K3HB-HTA-BCD1 Manual.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-HTA-BCD1 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-BCD1 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-BCD1 AC/DC24
Type of input: AC current input. Output type
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L1AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-FLK1AT11 AC100-240
OMRON Temperature panel K3HB-HTA-FLK1AT11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Voltage and current panel meter
K3HB-XVA-BCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-BCD1 AC100-240
Type of input: AC voltage input. Output type