Input type: Rotary pulse.
Supply voltage: 24 VAC/VDC.
Output: None.
Highly Visible LCD Display with 2-color (Red and Green) LEDs.
Contact, NPN, PNP, or voltage pulse input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Includes scaling, auto-zero time, startup compensation time functions K3HB-HTA-CPAC11 Communications Manual.
Easy confirmation of max/min display
K3HB-HTA-CPAC11
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Compo,
nent Recognition Program of UL.
CE marking.
Built-in external power supply (12 VDC, 40 mA) K3HB-HTA-CPAC11 Communications Manual. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-HTA-CPAC11 Communications Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation K3HB-HTA-CPAC11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-HTA-CPAC11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.