Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control G3RV-SR500-D AC/DC24 PDF datasheet.
RS-485 communications to set manipulated variables and,
monitor load current
G3RV-SR500-D AC/DC24
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified G3RV-SR500-D AC/DC24 PDF datasheet. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work G3RV-SR500-D AC/DC24 PDF datasheet.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 75 A, 180 to 480 VAC.
Rated input voltage: 100 to 240 VAC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No.
Applicable load: 45 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heatt,
Sinks G3RV-SR500-D AC/DC24 datasheet PDF catalog. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output cuurrents G3RV-SR500-D AC/DC24 datasheet PDF catalog. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification).